Harvest - LED Status Light
Model M0013 and newer Libra Cart models feature a status LED on their circuit board which can be viewed by removing the lid of the unit. M0018 Libra Carts have a viewing window built into the lid so removal is not necessary.
The LED status light will blink every 10 seconds (2-3 seconds when 12V power is detected). The hardware's current status can be determined by the number of consecutive blinks in a sequence.
| Number of Blinks Per Sequence | Status | Recommended Troubleshooting |
| 0 | No power detected. |
If using a 3.6V battery for power, test the battery while seated. If the battery shows under 3V of power, try a new battery. If using 12V power, test the end of the power cable and ensure it reads 12V. If cable/battery power tests are successful, but light does not activate contact Agrimatics support. |
| 1 | Power input detected, not paired to any nearby mobile devices. | Consult our Bluetooth troubleshooting guide, if hardware is receiving power, but not connecting as expected. |
| 2 | Power input detected, connected to at least one nearby mobile device. |
Expected state for properly connected Libra Hardware. If Primary device is still not receiving readings, check around for other devices that could be connected. |
| 3 | Internal error. | It is normal for the system to blink three times on initial power up. If the sequence continues after that: contact Agrimatics support. |