Harvest - LED Status Light

Model M0013 and newer Libra Cart models feature a status LED on their circuit board which can be viewed by removing the lid of the unit. M0018 Libra Carts have a viewing window built into the lid so removal is not necessary.


The LED status light will blink every 10 seconds (2-3 seconds when 12V power is detected). The hardware's current status can be determined by the number of consecutive blinks in a sequence.


Number of Blinks Per Sequence Status Recommended Troubleshooting
0 No power detected.

If using a 3.6V battery for power, test the battery while seated. If the battery shows under 3V of power, try a new battery.

If using 12V power, test the end of the power cable and ensure it reads 12V.

If cable/battery power tests are successful, but light does not activate contact Agrimatics support.

1 Power input detected, not paired to any nearby mobile devices. Consult our Bluetooth troubleshooting guide, if hardware is receiving power, but not connecting as expected.
2 Power input detected, connected to at least one nearby mobile device.

Expected state for properly connected Libra Hardware.

If Primary device is still not receiving readings, check around for other devices that could be connected.

3 Internal error. It is normal for the system to blink three times on initial power up. If the sequence continues after that: contact Agrimatics support.