Harvest - Calibration
This should be done after your Rated Capacity and Sensitivity Numbers are inputted.
- Ensure load cell ratings (Rated Capacity and Sensitivity) have been found and entered in the Device tab. Click here for an article on how to set your load cell ratings.
- Ensure the Libra Cart device and Libra Harvest app are paired and connected.
- Ensure the grain cart is empty and on level ground.
- Select the Device tab and tap Zero Scale.
- Select the Display tab and fill the grain cart.
- Tap Tare on the Display tab and then unload the cart into an empty truck, noting the amount unloaded (record as positive).
- Weigh the load with a trusted scale.
- Select the Device tab, tap the blue Calibration number and enter the weight from the trusted scale as the Certified Reading.
- Enter the noted weight from the app's Display as the Cart Reading.
- Tap Next to compute a new Calibration Factor.
- Tap Save to confirm Calibration.