Harvest - Inconsistent Weighing
If the Libra Harvest app is not weighing consistently and has been calibrated properly, there may be an issue with the load cell(s).
- Ensure the Minimum Load is set to 1000 lb in the Settings tab by tapping 🖊️ to the right of the corresponding paired device.
- Ensure the cart’s load cell junction box cable is connected and secured to the Libra Cart device.
- Inspect all the wiring and junction box connections. Check for any cabling that is rubbed, damaged, or pinched. Inspect the load cells and ensure none have been installed upside down.
- Assuming there is a stable weight when the grain cart is parked, apply weight (perhaps your body weight) to each of the cart’s load cells to ensure the scale weight goes up by the same amount no matter where weight is added on the cart. This verifies there is an equal signal from all load cells.
- If the weight is not stable when parked, start disconnecting one load cell at a time from the junction box. This should point towards the source of the wondering signal.
- If a faulty load cell or cable isn't obvious, it could be a junction box issue. Check for corrosion on the circuit board or moisture inside if the junction box is an open enclosure (screw terminal) style.
- Tap Send Diagnostics in the Devices tab to send Agrimatics an email with all weight measurements collected by your Libra Harvest app. When sending diagnostics, please add some descriptive notes to the email to ensure that we understand the problem or the specific need.